Spesifikasi :
Accessories Included:USB charger, power cable, and clips
Automatic Buffer Recognition:Yes
Backlight:Yes
Cable Length:1 m
Calibration:Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Calibration Intervals/Alerts/Reminder:Off, selectable from 2 hours to 7 days
Certifications:CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS
Conductivity measurement: Temperature correction:None; Linear; NaCl Non-Linear Natural Water.
Conductivity Measurement Range:Yes
Custom Calibration Standards:Yes
Data Export:USB connection to PC or USB storage device (limited to the storage device capacity).
Data Memory:5000 data points
Data Storage:Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode.
Dimensions (H x W x D):63 mm x 97 mm x 220 mm
Display:Up to 3 parameters at a time, dependent on HQ model
Display Type:536x336 Mono-TFT
Enclosure Rating:IP67 (with battery compartment installed)
GLP Features:Date; Time; Sample ID; Operator ID, Calibration
Inputs:1
Instrument:Portable
ISE Direct Measurement Range:No
ISE Electrode Calibration:No
Kit?:Yes
Languages:English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian
Lock Function:Continuous / Auto-stabilization ("press to read") / At Interval
Measurement Method:Probe specific programmed method settings
Model:HQ1140 EC/TDS/1 Channel
mV Measurement at Stable Reading:No
mV Measurement Range:No
mV Resolution:0.1 mV
Operating Error Messages:Clear text error messages displayed
Operating Humidity:90% (non-condensing)
Operating Interface:Soft Touch Keypad
Operating Temperature:0 - 60 °C
Parameter:Conductivity/Total Dissolved Solids (TDS)
Power Supply:Rechargeable lithium-ion battery 18650 (internal)
Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external)
Probes included:CDC40101
Probe Type:Intellical Standard Laboratory or Rugged Field
Protection Class:IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external
Region:US
Salinity Measurement Range:0 - 42 (ppt) (‰)
Salinity Resolution:0.01 (ppt) (‰)
Sensor A:CDC40101
Sensor B:None
Sensor C:None
Software available:Claros
Storage Conditions:-20 - 60 °C, max. 90% relative humidity (non-condensing)
TDS Measurement Range:0.00 mg/L - 50.0 g/L NaCl
TDS Resolution:0.01 mg/L - 0.1 g/L upon measuring range
Temperature Compensation:Automatic Temperature compensation for pH
Temperature Measurement:°C or °F
Temperature Resolution:0.1 °C
Type of measurement:Field Measurements
Warranty:12 months
Weight:519 g (Meter only)
What's included?:LEV015.53.1140A HQ1140 Portable EC/TDS Meter, 1 channel
CDC40101 Intellical conductivity cell, 1 m cable
LEZ015.99.A001A HQ standard electrode field case
LEZ015.99A003A HQ hand strap & kickstand
LEZ015.99.A004A HQ protective glove
2097000 Disposable wipes, 11x22 cm, pk/280
2771420 Singlet single-use conductivity standard solution, 1413 µS/cm, KCl, 20 mL
User manuals