SPECIFICATIONS :
Accessories Included:No
Automatic Buffer Recognition:Yes
Backlight : Yes
Calibration :
Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Calibration Intervals/Alerts/Reminder : Off, selectable from 2 hours to 7 days
Certifications : CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS
Data Export : USB connection to PC or USB storage device (limited to the storage device capacity).
Data Memory : 5000 data points
Data Storage : Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode.
Dimensions (H x W x D) : 63 mm x 97 mm x 220 mm
Display : Up to 3 parameters at a time, dependent on HQ model
Display Lock Function : Continuous / Auto-stabilisation ("press to read") / At Interval
Display Type : 536x336 Mono-TFT
Enclosure Rating : IP67 (with battery compartment installed)
GLP Features : Date; Time; Sample ID; Operator ID, Calibration
Inputs : 1
Instrument : Portable
ISE Direct Measurement Range : No
ISE Electrode Calibration : No
Kit? : Meter only
Languages :
English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian
Measurement method : Probe specific programmed method settings
Model : HQ1110 pH/ORP/1 Channel
mV Measurement at Stable Reading : No
mV Measurement Range : No
Operating Error Messages : Clear text error messages displayed
Operating Humidity : 90% (non-condensing)
Operating Interface : Soft Touch Keypad
Operating Temperature : 0 - 60 °C
ORP Electrode Calibration : Predefined ORP standards (including Zobell's solution)
Parameter : pH/Oxidation Reduction Potential (ORP)
pH Buffer Sets :
Colour-coded: 4.01, 7.00, 10.01 pH;
IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45
DIN: 1.09, 4.65, 9.23
User-defined custom buffer sets
pH Electrode calibration :
1 - 3 Calibration points
Calibration summary data logged and displayed
pH Measurement Range : 0 - 14 pH
pH Resolution : Selectable:
0.001/0.01/0.1 pH
Power supply :
Rechargeable lithium-ion battery 18650 (internal)
Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external)
Probes included : None
Probe Type : Intellical Standard Laboratory or Rugged Field
Protection Class:IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external
Sensor A : None
Sensor B : None
Sensor C : None
Storage conditions : -20 - 60 °C, max. 90% relative humidity (non-condensing)
Temperature Compensation : Automatic Temperature compensation for pH
Temperature Measurement : °C or °F
Temperature Resolution : 0.1 °C
Type of measurement : Field Measurements
Weight : 519 g (Meter only)
What's included?
: HQ1110 Portable pH/ORP Meter, 1 channel, includes manuals, Li-Ion batteries, USB charger with Power Cable.